Megger MEG 10-01 NEW |
10kV Insulation Tester
The MEG 10-01 offers the ability to test insulation to 10kV, to comply
with IEEE43: 2000. Micro processor control allows automatic insulation
resistance and polarisation index tests, and results storage and
download give full diagnostic information. |
| |
|
|
| |
|
|
|
 |
TTR550503 NEW
Three-Phase Transformer Turns Radio Test Set
Measures three phases simultaneously, the turns ratio of power,
instrument and distribution transformers. With a turns ratio range up to
10,000:1 and a 0.1% accuracy and only weighing 7.5kg, the TTR is ideal
for testing complex three-phase substation power transformers quickly
and accurately, minimizing the possibility of errors. The performance of
the TTR has been further enhanced by improved software allowing improved
reporting and remote control from a PC or laptop. |
|
|
|
| |
|
|
|
 |
Megger OTS60PB |
Portable Automatic Testing
The smallest lightest fully automatic portable oil test set available
with test voltage up to 60kV. Internal rechargeable battery for
operation in remote locations. Optional printer and fully programmed
international test sequences. |
| |
|
|
| |
|
|
|
 |
Megger DET2/2 |
| |
|
High Resolution Earth Tester
High resolution to 1mohm. This level is required to measure resistivity
to adequate depth on many substation and communication sites.
Measurement of the low earth values required on many installations, to
meet Grip Potential Rise (GRP) requirements also, requires this
resolution to ensure valid results. Hardware and software noise
filtering to retain resolution under real test conditions. |
|
| |
|
|
|
 |
Megger BM25 |
| |
|
Analogue/digital auto
testing
Automated diagnostic testing in a tough field case. A cost-effective
combination of portability and productivity offering enhanced test data
with selectable test voltage and test time. |
| |
|
|
| |
|
|
|
 |
UNINTERRUPTIBLE POWER
SYSTEM
Single Phase -
250VA to 25KVA |
|
Three Phase - 15KVA to
150KVA |
| |
|
Designed to supply continuous power to critical
loads power during outages. Solves 100% of all power problems commonly
encountered. It protects against power sags, surges, transients,
brownouts and blackouts.
Backup times available from 10 minutes to several hours. Units are built
to be field expandable. |
|
| |
|
|
|
 |
RESILIENT SEAT GATE VALVES |
| |
|
Features
- WRC Listed.
- Low Operating Torgue.
- Bubble tight shut off.
- Unobstructed waterway-larger than
nominal on all sizes.
- Fully encapsulated gate.
- Double stem seals and dirt seal.
- O-Ring below stem collar to facilitate
reparking under pressure.
- Fusion Bonded Epoxy Coating inside and
out.
- Square bottom to facilitate storage.
- Full size range 50mm - 300mm.
- All seals by "O" Ring.
Test Pressure
- Body: 1.5 x PN
- Seat: 1.1 x PN
- Working Pressure: 16bar
Service Temperature
- Max. 600C.
Application
- Water,
Sewage.
|
|
| |
|
 |
|
CF70 Series CABLE FAULT
LOCATOR |
| |
|
Features
- Proof tester,
burner, thumper in one self-
contained unit.
- Burn currents to 100 mA.
- Impulse energies of 3750J to 7500J.
- Automatic and manual thumper mode.
- Operable from line voltage or generator.
- Single HV output for all modes.
- Isolated and shielded return current path.
- Zero start interlock.
- External interlock.
- Face panel window.
- Mode indicator lights.
- Electrically operated shorting solenoids with
mechanical ground assurance.
- Internal radar pickup for voltage decay
method
Benefits
- Positive faults
identification and location.
- Isolated return for increased operator
safety.
- One unit for all URD cable maintenance
testing.
- Visual ground verification.
- Precise impulse repetition.
- Variable impulse rate from 3 to 30 seconds. |
|
| |
|
 |
800PL Series DC HIPOT
TESTERS |
| |
|
Features
- Rugged and
portable.
- One-piece construction.
- Shielded output cable.
- Guard circuit.
- Full-wave voltage doubling rectifier circuit.
- Zero start interlock.
- Internal discharge on HV OFF.
- Meter accuracy + 2% full scale.
- 5 mA current rating for cable charging.
- External interlock provisions.
- Three range current meter.
- Four range current meter.
- No internal leakage at full load.
- Instantaneous overload relay.
- Surge-limiting resistors in HV output.
Benefits
- Ideal for field
testing - lightweight,
compact, and rugged.
- Safe and easy operation.
- No exposed high voltage.
- Accurate leakage current measurement.
- Guard circuit eliminates stray leakage
currents. |
|
| |
|
|
|
 |
CABLE DYNAMICS TDR 1130 |
| |
|
Features
- Digital TDR.
- LCD Display.
- Internal Trace Storage.
- 16 Sample Memory.
- Serial Port with Software for Waveform
Download.
- Battery Operated.
Benefits
- Pre-Locate
Faults.
- Use the 1130 to Diagnose Cable Fault.
- Easy to Use.
- Compatible with Common "Thumpers".
- Reduce Outage Time.
- Reduce Cable Damage.
- Simplified Operator Training.
|
| |
|
|
|